Doprava nad 2350,- ZDARMA

Countercurrent pump CONTRA 4 - 84m3/h - for salt water

Code: 4400
FREEFREE
New Contra
€592,08 €489,32 excl. VAT
In stock (1 pcs)
Delivery to:
29.10.2024
"

Quality Spanish counter-current pump 400V, 84m3/h at 4m water column.

Useable for both saltwater and seawater.

Most popular anti-surge pump

90mm or 75mm connection, both included.

Pool Tip: These pumps are trouble-free and will last for many years.

"

Detailed information

Kamenná prodejna
Store
in Pardubice
Doprava zdarma
Shipping across
whole Europe
Největší výběr
Largest selection of
pool treatments
1000+
1000+ products
to ship immediately
Možnost vrácení
Possibility of return
within 30 days

Product detailed description

Pool Specialist Opinion - Review

  • + High performance and pump efficiency
  • Compatible with Elegance and NEWBCC series
  • Resistant to salt water thanks to AISI 316 stainless steel
  • Robust construction made of glass fibre reinforced polypropylene
  • Higher purchase price

"The CONTRA 4 pump is ideal for demanding pool applications. With its 84 m3/hr capacity and saltwater capability, it offers an unrivalled solution for your pool needs."

Team Poolservis

Powerful and durable counter-current pump

The CONTRA 4 pump, sized for countercurrents, water attractions and gargoyles, is equipped with a hair pre-filter and offers an excellent performance of 84 m3/hr. The pump body made of glass fibre reinforced polypropylene and AISI 316 stainless steel components ensure long life and corrosion resistance.

Installation and maintenance

The installation of the CONTRA 4 pump is easy and trouble-free. The pump must be mounted on a solid and smooth surface using the two mounting holes in the pump leg. It is important to protect the pump from flooding and frost, and in outdoor installations also from rain.

Safety instructions and winterization

To work safely and efficiently, it is important to follow the installation and maintenance instructions. It is recommended to store the pump in a dry area after the end of the season to prolong its life. If necessary, the pump can be removed without draining the entire pipeline due to the location of the shut-off valves on the suction and pressure sides.

Technical specifications and compatibility

The pump is compatible with the Elegance and NEWBCC series, ensuring wide applicability. With a voltage of 400V, an input of 3 kW and a maximum water temperature of 40°C, the pump meets all the requirements for modern pool technology.

The pump body is made of hardened polypropylene with glass fibre. Bearings, packing and pump shaft made of AISI 316 stainless steel.

The pump is rated for countercurrents, water attractions, gargoyles, etc.

 Contra series pumps are compatible with Elegance and NEWBCC series

Technical parameters:

    .
  • Pump with hair pre-filter
  • .
  • IP55 protection
  • Motor. 50Hz / 2900rpm
  • Includes thermal protection
  • Power cable not included !!!
  • Parameter Value
    Water flow 84 m3/hr at 4m water column
    voltage 400V
    Power 3 kW
    Max. water temperature 40°C
    Coverage IP55
    Connection - threaded 75mm or 90mm
    Salt water suitable yes
    Self-priming no - please place under water

Untitled 16

Pump Features

  • Each piece is tested
  • Glass fibre reinforced polypropylene pump body and diffuser give superior durability
  • Pump axis is not in contact with the pumped water

Which pool pump to choose

Package includes:

Pump including nut and reducer to 90mm or 75mm

English instructions

Untitled 17

When installing a CONTRA pool pump you could use:

You can connect the pump to the pool circuit using, for example, 75mm tubing. We recommend that you also insert a 75mm pool ball valve before and after the pump, especially if the pump is below the pool level. This will prevent the entire pool from leaking when handling the pump. Use pvc pool joint adhesive

to adhere.

 

Installation:

The pump must be mounted on a solid and smooth surface.The pump must be properly
fixed using the two attachment holes in the pump leg using two suitable
screws or threaded bolts to prevent noise and oscillation that can
interfere with the pump's operation.</p


The pump should be protected from possible flooding, proper ventilation should be ensured and
freeze should be avoided.If the pump is installed outdoors, it should
be protected from rain.

It is recommended to have closing valves on both the suction and pressure sides, so that the pump can be removed if necessary without draining the entire pipeline.</p


The suction pipe must be at least the same diameter as the pump inlet. On the pressure side, it is
recommended to connect a pipe of the same diameter as the pump outlet.
The suction pipe must be laid with a slight incline to the pump to prevent the formation of
air cushions.


After winterizing the pool it is recommended to put the pump in a dry area with a constant temperature (garage, etc.), this will extend the life of the pump, it will not rust as in a wet sump by the pool when it is cold in autumn and freezing in winter.

Untitled 18

Additional parameters

Category: Counterflow
Weight: 23 kg
Značka: Poolservis

Be the first who will post an article to this item!

Do not fill out this field:

Be the first who will post an article to this item!

Do not fill out this field:
document.write("