High-quality Spanish counter-current pump, 400V, 66m³/h at a water column of 4m.

Suitable for fresh, salt, and seawater.

A very common counter-current pump

Connection 75mm, both included in the package.

Pool expert's tip: These pumps are manufactured in Europe, are highly reliable, and last for many years.

Detailed information

Kamenná prodejna
Store
in Pardubice
Doprava zdarma
Shipping across
whole Europe
Největší výběr
Largest selection of
pool treatments
1000+
1000+ products
to ship immediately
Možnost vrácení
Possibility of return
within 30 days

Product detailed description

Opinion of a Pool Specialist - Review

  • + High performance and efficiency of the pump
  • Resistant to saltwater thanks to AISI 316 stainless steel
  • Robust construction made of fiberglass-reinforced polypropylene
  • Higher purchase price

“The NEWBCC pump is ideal for demanding pool applications. With its performance of 66m³/h and its ability to handle saltwater, it offers an unparalleled solution for your pool needs.”

Poolservis Team

Powerful and Durable Pump for Counter Currents

The NEWBCC pump is designed for counter currents, water attractions, and waterfalls. Its fiberglass-reinforced polypropylene body and AISI 316 stainless steel components ensure long life and corrosion resistance.

NEWBCC pump performance

Installation and Maintenance

The installation of the NEWBCC pump is easy and straightforward. The pump must be mounted on a solid and smooth surface using two mounting holes on the pump's base. It is important to protect the pump from flooding and frost, and for outdoor installations, from rain as well.

The pump is not self-priming and must be installed below the pool water level.

Safety Instructions and Winterization

To ensure safe and efficient operation, it is important to follow the installation and maintenance guidelines. After the season, it is recommended to store the pump in a dry area to extend its life. If necessary, the pump can be removed without draining the entire pipeline, thanks to the placement of shut-off valves on both the suction and discharge sides.

Technical Specifications and Compatibility

With a voltage of 400V, a power input of 2,6 kW, and a maximum water temperature of 40°C, the pump meets all requirements for modern pool technology.

The pump body is made of fiberglass-reinforced polypropylene. Bearings, seals, and the pump shaft are made of AISI 316 stainless steel.

The pump is designed for counter currents, water attractions, waterfalls, and more.

Technical Parameters:

  • Protection rating: IP55
  • Motor: 50Hz / 2900rpm
  • Includes thermal protection
  • Power cable is not included!
  • Parameter Value
    Water Flow 66 m³/h at a 4m water column
    Voltage 400V
    Power Input 2,6 kW
    Max. Water Temperature 40°C
    Protection Rating IP55
    Connection - Thread - Adhesive 75mm
    Suitable for Saltwater Yes
    Self-Priming No - must be placed below water level

Pump Features:

  • Each unit is tested
  • Pump body and diffuser made of fiberglass-reinforced polypropylene for superior durability
  • The pump shaft does not come into contact with the pumped water

Which Pool Pump to Choose?

The package includes:

Pump, including nut and 75mm reducer

Czech manual

When Installing the CONTRA Pool Pump, You May Need:

You can connect the pump to the pool circuit using 75mm pipes, for example. We also recommend adding a ball valve before and after the pump, especially if the pump is below the pool water level. This will prevent the entire pool from draining during pump maintenance. Use pool adhesive for PVC connections.

Installation:

The pump must be mounted on a solid and smooth surface. The pump must be securely
fastened using two mounting holes on its base with appropriate screws or threaded studs to prevent noise and vibration, which could affect pump performance.

The pump must be protected from potential flooding, ensure proper ventilation, and protect it from frost. If the pump is installed outdoors, it should be
shielded from rain.

We recommend installing shut-off valves on both the suction and discharge sides, so the pump can be removed without draining the entire pipeline if necessary.

The suction pipe must have at least the same diameter as the pump inlet. On the discharge side, a pipe diameter matching the pump outlet is recommended. The suction pipe should be laid with a slight upward slope toward the pump to avoid air pockets.

After winterizing the pool, it is recommended to store the pump in a dry area with a stable temperature (such as a garage). This will extend the pump's life, preventing rust as opposed to leaving it in a damp sump near the pool during autumn and winter conditions.

Additional parameters

Category: Counterflow
Weight: 23 kg